LCD Scrren Hospital Anesthesia System Clinical Anesthesia Apparatus Machine
Description:
Anesthesia machine structure: flow meter, ventilator, breathing circuit, pipeline and other components
PCV and SIMV+PS modes ensure flexibility in ventilation, machine doable for both pediatric and adult operation
Optional monitoring functions: CO2 and anesthetic gas
Flowmeter provides minimum 25% concentration of oxygen in O2 /N2O mixture
Breathing system easy to remove and clean, fully autoclavable, optional CO2 bypass
Enhances usability with auxiliary oxygen, suction, auxiliary power source, monitor arm, infusion pump etc.
CE marked, meets EU clinical requirement
Technical Specification:
Description:
Anesthesia machine structure: flow meter, ventilator, breathing circuit, pipeline and other components
PCV and SIMV+PS modes ensure flexibility in ventilation, machine doable for both pediatric and adult operation
Optional monitoring functions: CO2 and anesthetic gas
Flowmeter provides minimum 25% concentration of oxygen in O2 /N2O mixture
Breathing system easy to remove and clean, fully autoclavable, optional CO2 bypass
Enhances usability with auxiliary oxygen, suction, auxiliary power source, monitor arm, infusion pump etc.
CE marked, meets EU clinical requirement
Technical Specification:
Product name | LCD Scrren Hospital Anesthesia System Clinical Anesthesia Apparatus Machine |
Physical & Environment Specifications | Dimensions(W×H×D): 704mm × 1403mm × 750mm Weight: 115kg (including trolley base and 2 vaporizers, without cylinder) Operation Temperature: +10~+40°C Operation Humidity: ≤80% (noncondensing) Storage Temperature: -20~+55°C Storage Humidity: ≤93% (noncondensing) |
Electrical Specifications | Mains: 100~240V AC, 50/60Hz Battery: 24V DC, minimum 120 min Outlets: 4 on back, 1.5A individual |
Pneumatic Specifications | Gas Supply: Air, O2, N2O; 280kPa ~ 600kPa Flowmeters: O2 Range: 0~1L/min; 1~10L/min N2O Range: 0~1L/min; 1~10L/min Air Range: 0~1L/min; 1~12L/min Auxiliary O2 Range: 0 ~15 L/min Flowmeter backlight Gas System: Oxygen supply failure alarm N2O-cut-off system O2 flush: 25~75L/min ACGO: Optional auxiliary common gas outlet AGSS: Optional anesthetic gas scavenging system |
Breathing System Specifications | Operational Modes: Closed, Semi-closed, Semi-open CO2 Canister: 2 Loose fill (3L) or 2 prepacks, optional single canister (1.8 L) APL Range: Spontaneous breathing (SP) - 70 cmH2O Material: Autoclavable (except O2 cell and mechanical pressure gauge) CO2 bypass: Optional |
Ventilator Specifications | Driven Mode: Pneumatically driven and electronically controlled Patient Types: Adult, Pediatric Ventilation Modes: IPPV, PCV, SIMV+PS, PS and Manual Setting Modes: Touch key & navigator wheel knob Tidal Volume: 20~1500ml Ventilation Frequency: 4~100bpm I:E Ratio: 4:1~1:8 Pressure (inspired) Range: 5~70cmH2O Pressure (support) Range: 3~50cmH2O PEEP: Off,3~30 cmH2O Tslope: 0~2s Inspiratory Plateau: Off, 5%~60%Ti Trigger Sensitivity: 1~15L/min Compensation: Compliance and leakage compensation, fresh gas compensation and altitude compensation |
Ventilator Monitoring | Display: 10.4" TFT color screen Pressure: Ppeak, Pplat, Pmean, PEEP Volumes: MV, Vt, Freq Gas: O2 Concentration, optional CO2, Agent and MAC Graph Display: P-t, F-t, P-V, F-V loops(can be saved), optional CO2-t Alarm: High Airway Pressure/Low Airway Pressure Sustained airway pressure High Minute Volume/Low Minute Volume High FiO2/Low FiO2 High Breath Rate O2 Supply failure Power failure Apnea Alarm Alarm Silence: 110 seconds |
Vaporizer | Support two vaporizers Agent: Halothane, Enflurane, Isoflurane, Sevoflurane Installation Mode: Selectatec with interlock, optional standby vaporizer parking holder Filling Type: Pour Fill, Key Fill, Quik-Fil |